This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
extensions:teemip-cable-mgmt [2024/02/22 13:00] – [Revision History] cnaud | extensions:teemip-cable-mgmt [2024/04/09 08:51] – [Configuration] cnaud | ||
---|---|---|---|
Line 32: | Line 32: | ||
===== Revision History ===== | ===== Revision History ===== | ||
^ Version | ^ Version | ||
- | | 1.3.0 | 2024-0x-xx | + | | 1.3.0 | 2024-0x-xx |
- | | **1.2.0** | + | | **1.2.0** |
- | | 1.1.0 | 2023-07-24 | + | | 1.1.0 | 2023-07-24 |
- | | 1.0.0 | 2022-12-04 | + | | 1.0.0 | 2022-12-04 |
===== Features ===== | ===== Features ===== | ||
Line 67: | Line 67: | ||
===== Configuration ===== | ===== Configuration ===== | ||
- | No specific configuration is required in TeemIp' | + | No specific configuration is required in TeemIp' |
+ | |||
+ | < | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ), | ||
+ | ), | ||
+ | </ | ||
+ | |||
+ | These should be added to the Modules specific part of the configuration file. | ||
===== Patch Panel ===== | ===== Patch Panel ===== | ||
Line 82: | Line 93: | ||
| Location | Foreign key to a(n) Location | Yes | | | Location | Foreign key to a(n) Location | Yes | | ||
| Capacity | Number of network sockets that the panel can host | No | | | Capacity | Number of network sockets that the panel can host | No | | ||
- | | Connector | Foreign key to a(n) Interface Connector \\ Brought by the [[extensions: | + | | Connector | Foreign key to a(n) Interface Connector \\ Brought by the [[extensions: |
+ | | External reference | Alphanumeric string | ||
| Description | Multiline character string | No | | | Description | Multiline character string | No | | ||
| **Rack Information** ||| | | **Rack Information** ||| | ||
Line 139: | Line 151: | ||
| Patch panel | Foreign key to a(n) Patch Panel | No | | | Patch panel | Foreign key to a(n) Patch Panel | No | | ||
| Organization | Organization that the patch panel belongs to | N/A | | | Organization | Organization that the patch panel belongs to | N/A | | ||
+ | | External reference | Alphanumeric string | No | | ||
| Comment | Multiline character string | No | | | Comment | Multiline character string | No | | ||
| **Front End Information** ||| | | **Front End Information** ||| | ||
Line 187: | Line 200: | ||
===== Cross Connect ===== | ===== Cross Connect ===== | ||
{{icons8-data-transfer.svg | {{icons8-data-transfer.svg | ||
- | FIXME | ||
A cross connect represents the cabling necessary to establish a direct link between two separate organizations in a data center, thus allowing the establishment of a private network link and eliminating the need to connect them using the internet. | A cross connect represents the cabling necessary to establish a direct link between two separate organizations in a data center, thus allowing the establishment of a private network link and eliminating the need to connect them using the internet. | ||
Line 193: | Line 205: | ||
^ Name ^ Type ^ Mandatory? | ^ Name ^ Type ^ Mandatory? | ||
| **General Information** ||| | | **General Information** ||| | ||
- | | Code | Alphanumeric string | Yes | | + | | Name | Alphanumeric string | Yes | |
- | | Status| Possible values: | + | | Organization | Foreign key to a(n) Organization | Yes | |
- | | Location | Foreign key to a(n) Location | Yes | | + | | Reference | Alphanumeric string | No | |
- | | Rack | Foreign key to a(n) Rack | No | | + | | Peer Organization | Foreign key to a(n) Organization | Yes | |
- | | Patch panel | Foreign key to a(n) Patch Panel | No | | + | | Peer Reference | Alphanumeric string | No | |
- | | Organization | + | | Status| Possible values: |
- | | Comment | + | | Cable category & type | Foreign key to a(n) Cable type | No | |
- | | **Front End Information** ||| | + | | Business criticality | Possible values: low, medium, high | No | |
- | | Connector | + | | Move to production date | Date (year-month-day) |
- | | Device | + | | Description | Multiline character string | No | |
- | | Physical interface | + | | **Local Unit Information** ||| |
- | | Network socket | Foreign key to a(n) Network Socket | No | | + | | Location | Foreign key to a(n) Location |
+ | | Rack | Foreign key to a(n) Rack | Yes | | ||
+ | | Patch panel | Foreign key to a(n) Patch Panel | Yes | | ||
+ | | Primary Network socket | ||
+ | | Secondary Network socket | ||
+ | | **Peer Unit Information** ||| | ||
+ | | Location | ||
+ | | Rack | Foreign key to a(n) Rack | Yes | | ||
+ | | Patch panel | Foreign key to a(n) Patch Panel | Yes | | ||
+ | | Primary Network socket | ||
+ | | Secondary | ||
| **Back End Information** ||| | | **Back End Information** ||| | ||
| Back end network socket | Foreign key to a(n) Network Socket | No | | | Back end network socket | Foreign key to a(n) Network Socket | No | | ||
- | |||
=== Tabs === | === Tabs === | ||
^ Tab ^ Description | ^ Tab ^ Description | ||
- | | Cables | + | | Contacts |
+ | | Documents | All the documents linked | ||
+ | | Wiring | Wiring diagram | ||
Line 219: | Line 242: | ||
{{ classdisplay_crossconnect.png }} | {{ classdisplay_crossconnect.png }} | ||
+ | === Finding Wiring Paths === | ||
+ | A cross connect documents a link between one or two network socket hosted in a patch panel sitting in a rack of a given organization and one or two peer network socket hosted in a peer patch panel sitting in a peer rak of a peer organization. This action will display all the available cabling paths that may be establish to connect 2 network sockets that answer to the previous conditions. | ||
+ | {{ classdisplay_crossconnect_find_path.png }} | ||
+ | Network admin may select one of the offered path and manually create it within TeemIP. | ||
===== Physical Interface ===== | ===== Physical Interface ===== | ||
{{icons8-globe-wire.png | {{icons8-globe-wire.png | ||
Line 269: | Line 295: | ||
Friendly name of a front end network cable is automatically computed as the concatenation of the two network sockets' | Friendly name of a front end network cable is automatically computed as the concatenation of the two network sockets' | ||
+ | |||
+ | === Tabs === | ||
+ | ^ Tab ^ Description | ||
+ | | Documents | All documents linked to the front end network cable | | ||
<note warning> | <note warning> | ||
Line 299: | Line 329: | ||
Friendly name of a back end network cable is automatically computed as the concatenation of the two network sockets' | Friendly name of a back end network cable is automatically computed as the concatenation of the two network sockets' | ||
+ | |||
+ | === Tabs === | ||
+ | ^ Tab ^ Description | ||
+ | | Documents | All documents linked to the back end network cable | | ||
<note warning> | <note warning> | ||
Line 330: | Line 364: | ||
Friendly name of a device network cable is automatically computed as the concatenation of the network socket' | Friendly name of a device network cable is automatically computed as the concatenation of the network socket' | ||
+ | |||
+ | === Tabs === | ||
+ | ^ Tab ^ Description | ||
+ | | Documents | All documents linked to the device network cable | | ||
<note warning> | <note warning> | ||
Line 361: | Line 399: | ||
Friendly name of a device network cable is automatically computed as the concatenation of the two interface' | Friendly name of a device network cable is automatically computed as the concatenation of the two interface' | ||
+ | |||
+ | === Tabs === | ||
+ | ^ Tab ^ Description | ||
+ | | Documents | All documents linked to the direct network cable | | ||
<note warning> | <note warning> | ||
Line 396: | Line 438: | ||
=== Tabs === | === Tabs === | ||
^ Tab ^ Description | ^ Tab ^ Description | ||
- | | Patch Panels | All the patch panels that the cable is connected to | | + | | Documents | All documents linked to the breakout cable | |
+ | | Patch Panels | ||
- | The relation holds a " | + | (*) The relation holds a " |
<note tip> | <note tip> | ||
Line 404: | Line 447: | ||
* Value is computed as the capacity minus the maximum of used links with a given rack. | * Value is computed as the capacity minus the maximum of used links with a given rack. | ||
* The breakout cable / patch panel relation holds a "Used Links" parameter telling how many links are consummed by the connection. | * The breakout cable / patch panel relation holds a "Used Links" parameter telling how many links are consummed by the connection. | ||
+ | * When a relation is created, the "Used Links" attribute is initialized with the value of the patch panel' | ||
</ | </ | ||
<note warning> | <note warning> |