This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
extensions:teemip-cable-mgmt [2024/02/22 15:09] – [Direct Network Cable] cnaud | extensions:teemip-cable-mgmt [2024/02/23 17:30] – [Device Network Cable] cnaud | ||
---|---|---|---|
Line 82: | Line 82: | ||
| Location | Foreign key to a(n) Location | Yes | | | Location | Foreign key to a(n) Location | Yes | | ||
| Capacity | Number of network sockets that the panel can host | No | | | Capacity | Number of network sockets that the panel can host | No | | ||
- | | Connector | Foreign key to a(n) Interface Connector \\ Brought by the [[extensions: | + | | Connector | Foreign key to a(n) Interface Connector \\ Brought by the [[extensions: |
+ | | External reference | Alphanumeric string | ||
| Description | Multiline character string | No | | | Description | Multiline character string | No | | ||
| **Rack Information** ||| | | **Rack Information** ||| | ||
Line 112: | Line 113: | ||
With the extension [[https:// | With the extension [[https:// | ||
+ | FIXME | ||
{{ classdisplay_patchpanel-dcviewext.png }} | {{ classdisplay_patchpanel-dcviewext.png }} | ||
Line 139: | Line 141: | ||
| Patch panel | Foreign key to a(n) Patch Panel | No | | | Patch panel | Foreign key to a(n) Patch Panel | No | | ||
| Organization | Organization that the patch panel belongs to | N/A | | | Organization | Organization that the patch panel belongs to | N/A | | ||
+ | | External reference | Alphanumeric string | No | | ||
| Comment | Multiline character string | No | | | Comment | Multiline character string | No | | ||
| **Front End Information** ||| | | **Front End Information** ||| | ||
Line 187: | Line 190: | ||
===== Cross Connect ===== | ===== Cross Connect ===== | ||
{{icons8-data-transfer.svg | {{icons8-data-transfer.svg | ||
- | FIXME | ||
A cross connect represents the cabling necessary to establish a direct link between two separate organizations in a data center, thus allowing the establishment of a private network link and eliminating the need to connect them using the internet. | A cross connect represents the cabling necessary to establish a direct link between two separate organizations in a data center, thus allowing the establishment of a private network link and eliminating the need to connect them using the internet. | ||
Line 193: | Line 195: | ||
^ Name ^ Type ^ Mandatory? | ^ Name ^ Type ^ Mandatory? | ||
| **General Information** ||| | | **General Information** ||| | ||
- | | Code | Alphanumeric string | Yes | | + | | Name | Alphanumeric string | Yes | |
- | | Status| Possible values: | + | | Organization | Foreign key to a(n) Organization | Yes | |
- | | Location | Foreign key to a(n) Location | Yes | | + | | Reference | Alphanumeric string | No | |
- | | Rack | Foreign key to a(n) Rack | No | | + | | Peer Organization | Foreign key to a(n) Organization | Yes | |
- | | Patch panel | Foreign key to a(n) Patch Panel | No | | + | | Peer Reference | Alphanumeric string | No | |
- | | Organization | + | | Status| Possible values: |
- | | Comment | + | | Cable category & type | Foreign key to a(n) Cable type | No | |
- | | **Front End Information** ||| | + | | Business criticality | Possible values: low, medium, high | No | |
- | | Connector | + | | Move to production date | Date (year-month-day) |
- | | Device | + | | Description | Multiline character string | No | |
- | | Physical interface | + | | **Local Unit Information** ||| |
- | | Network socket | Foreign key to a(n) Network Socket | No | | + | | Location | Foreign key to a(n) Location |
+ | | Rack | Foreign key to a(n) Rack | Yes | | ||
+ | | Patch panel | Foreign key to a(n) Patch Panel | Yes | | ||
+ | | Primary Network socket | ||
+ | | Secondary Network socket | ||
+ | | **Peer Unit Information** ||| | ||
+ | | Location | ||
+ | | Rack | Foreign key to a(n) Rack | Yes | | ||
+ | | Patch panel | Foreign key to a(n) Patch Panel | Yes | | ||
+ | | Primary Network socket | ||
+ | | Secondary | ||
| **Back End Information** ||| | | **Back End Information** ||| | ||
| Back end network socket | Foreign key to a(n) Network Socket | No | | | Back end network socket | Foreign key to a(n) Network Socket | No | | ||
- | |||
=== Tabs === | === Tabs === | ||
^ Tab ^ Description | ^ Tab ^ Description | ||
- | | Cables | + | | Contacts |
+ | | Documents | All the documents linked | ||
+ | | Wiring | Wiring diagram | ||
Line 219: | Line 232: | ||
{{ classdisplay_crossconnect.png }} | {{ classdisplay_crossconnect.png }} | ||
+ | === Finding Wiring Paths === | ||
+ | A cross connect documents a link between one or two network socket hosted in a patch panel sitting in a rack of a given organization and one or two peer network socket hosted in a peer patch panel sitting in a peer rak of a peer organization. This action will display all the available cabling paths that may be establish to connect 2 network sockets that answer to the previous conditions. | ||
+ | {{ classdisplay_crossconnect_find_path.png }} | ||
+ | Network admin may select one of the offered path and manually create it within TeemIP. | ||
===== Physical Interface ===== | ===== Physical Interface ===== | ||
{{icons8-globe-wire.png | {{icons8-globe-wire.png | ||
Line 341: | Line 357: | ||
=== Tabs === | === Tabs === | ||
^ Tab ^ Description | ^ Tab ^ Description | ||
- | | Documents | All documents linked to the network cable | | + | | Documents | All documents linked to the device |
<note warning> | <note warning> | ||
Line 376: | Line 392: | ||
=== Tabs === | === Tabs === | ||
^ Tab ^ Description | ^ Tab ^ Description | ||
- | | Documents | All documents linked to the network cable | | + | | Documents | All documents linked to the direct |
<note warning> | <note warning> | ||
Line 412: | Line 428: | ||
=== Tabs === | === Tabs === | ||
^ Tab ^ Description | ^ Tab ^ Description | ||
+ | | Documents | All documents linked to the breakout cable | | ||
| Patch Panels | All the patch panels that the cable is connected to | | | Patch Panels | All the patch panels that the cable is connected to | | ||
Line 420: | Line 437: | ||
* Value is computed as the capacity minus the maximum of used links with a given rack. | * Value is computed as the capacity minus the maximum of used links with a given rack. | ||
* The breakout cable / patch panel relation holds a "Used Links" parameter telling how many links are consummed by the connection. | * The breakout cable / patch panel relation holds a "Used Links" parameter telling how many links are consummed by the connection. | ||
+ | * When a relation is created, the "Used Links" attribute is initialized with the value of the patch panel' | ||
</ | </ | ||
<note warning> | <note warning> |