This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
extensions:teemip-cable-mgmt [2024/02/22 15:57] – [Cross Connect] cnaud | extensions:teemip-cable-mgmt [2024/03/06 17:52] – [Patch Panel] cnaud | ||
---|---|---|---|
Line 82: | Line 82: | ||
| Location | Foreign key to a(n) Location | Yes | | | Location | Foreign key to a(n) Location | Yes | | ||
| Capacity | Number of network sockets that the panel can host | No | | | Capacity | Number of network sockets that the panel can host | No | | ||
- | | Connector | Foreign key to a(n) Interface Connector \\ Brought by the [[extensions: | + | | Connector | Foreign key to a(n) Interface Connector \\ Brought by the [[extensions: |
+ | | External reference | Alphanumeric string | ||
| Description | Multiline character string | No | | | Description | Multiline character string | No | | ||
| **Rack Information** ||| | | **Rack Information** ||| | ||
Line 139: | Line 140: | ||
| Patch panel | Foreign key to a(n) Patch Panel | No | | | Patch panel | Foreign key to a(n) Patch Panel | No | | ||
| Organization | Organization that the patch panel belongs to | N/A | | | Organization | Organization that the patch panel belongs to | N/A | | ||
+ | | External reference | Alphanumeric string | No | | ||
| Comment | Multiline character string | No | | | Comment | Multiline character string | No | | ||
| **Front End Information** ||| | | **Front End Information** ||| | ||
Line 187: | Line 189: | ||
===== Cross Connect ===== | ===== Cross Connect ===== | ||
{{icons8-data-transfer.svg | {{icons8-data-transfer.svg | ||
- | FIXME | ||
A cross connect represents the cabling necessary to establish a direct link between two separate organizations in a data center, thus allowing the establishment of a private network link and eliminating the need to connect them using the internet. | A cross connect represents the cabling necessary to establish a direct link between two separate organizations in a data center, thus allowing the establishment of a private network link and eliminating the need to connect them using the internet. | ||
Line 286: | Line 287: | ||
=== Tabs === | === Tabs === | ||
^ Tab ^ Description | ^ Tab ^ Description | ||
- | | Documents | All documents linked to the network cable | | + | | Documents | All documents linked to the front end network cable | |
<note warning> | <note warning> | ||
Line 320: | Line 321: | ||
=== Tabs === | === Tabs === | ||
^ Tab ^ Description | ^ Tab ^ Description | ||
- | | Documents | All documents linked to the network cable | | + | | Documents | All documents linked to the back end network cable | |
<note warning> | <note warning> | ||
Line 355: | Line 356: | ||
=== Tabs === | === Tabs === | ||
^ Tab ^ Description | ^ Tab ^ Description | ||
- | | Documents | All documents linked to the network cable | | + | | Documents | All documents linked to the device |
<note warning> | <note warning> | ||
Line 390: | Line 391: | ||
=== Tabs === | === Tabs === | ||
^ Tab ^ Description | ^ Tab ^ Description | ||
- | | Documents | All documents linked to the network cable | | + | | Documents | All documents linked to the direct |
<note warning> | <note warning> | ||
Line 426: | Line 427: | ||
=== Tabs === | === Tabs === | ||
^ Tab ^ Description | ^ Tab ^ Description | ||
+ | | Documents | All documents linked to the breakout cable | | ||
| Patch Panels | All the patch panels that the cable is connected to | | | Patch Panels | All the patch panels that the cable is connected to | | ||